    BSL3 Series Brochure

    Innovative automatic safety door lock

    Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

    The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

    The door-locking system on this BSL-3 autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

    BSL3 autoclave lock
     

    sterile autoclave steam

    Steam generation

    A steam generator is incorporated in the sterilizer housing providing substantial benefits:

    • No heating elements and no reservoir for dirty water in the chamber
    • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
    • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
    • Accuracy better than ± 0.5 C with empty chamber
    • Quicker cooling as neither hot water in the chamber nor the separate steam generator need be cooled
    • After cooling, steam is immediately available for the next sterilization run.
     

    Pressure-safe up to 5 bar/150 °C

    The Systec biosafety autoclaves are designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing BSL3 series pass through autoclaves.

    Systec biosafety autoclave units are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

    Biosafety Level 3 autoclave chamber
     

    Biosafety Level 3 autoclave quality

    Quality materials quality manufacturing

    The pressure vessel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. The biosafety level 3 autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec D2D-Series sterilizer is ideal for use in clean room environments

    Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

     

    Controls – new generation

    The Systec biosafety double door autoclave units have “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The touch screen, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

    Menu-presented instructions in easy to read text form. An advanced touch screen with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position.

    BSL3 autoclave touch screen
     

    BSL-3 Autoclave Gallery

    [module-289]

Autoclave Videos


Autoclave Videos

Cooling options to fit your laboratory needs.

[module-280]

[module-295]

[module-296]

  • Double Door Autoclaves

    Double Door Autoclave

    Select size range

    [module-274]

    D2D Series Brochure

    Innovative automatic safety door lock

    Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

    The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

    The door-locking system on this double door autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

    double door autoclave lock
     

    autoclave steam generation

    Steam generation

    A steam generator is incorporated in the sterilizer housing providing substantial benefits:

    • No heating elements and no reservoir for dirty water in the chamber
    • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
    • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
    • Accuracy better than ± 0.5° C with empty chamber
    • Quicker cooling as neither the hot water in the chamber nor the separate steam generator need to be cooled
    • After cooling, steam is immediately available for the next sterilization run.
     

    Pressure-safe up to 5 bar/150 °C

    The Systec D2D-Series double door autoclave units are the first of its kind to be designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing pass through autoclave units.

    Systec pass through autoclave units are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

    pass through autoclave chamber
     

    D2D Series autoclave quality

    Quality materials quality manufacturing

    The pressure vessel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. The double door autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec D2D-Series sterilizer is ideal for use in clean room environments

    Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

     

    Controls – new generation

    The Systec D2D-Series double door autoclave units have “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The touch screen, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

    Menu-presented instructions in easy to read text form. An advanced touch screen with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position.

    Systec autoclave touchscreen
     

    D2D Series Autoclave Gallery

    [module-289]

  • Autoclave Videos


    Autoclave Videos

    Cooling options to fit your laboratory needs.

    [module-280]

    [module-295]

    [module-296]

  • Double Door Autoclaves 2021

    Double Door Autoclave

    Select size range

    [module-350]

    D2D Series Brochure

    Innovative automatic safety door lock

    Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

    The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

    The door-locking system on this double door autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

    double door autoclave lock
     

    autoclave steam generation

    Steam generation

    A steam generator is incorporated in the sterilizer housing providing substantial benefits:

    • No heating elements and no reservoir for dirty water in the chamber
    • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
    • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
    • Accuracy better than ± 0.5° C with empty chamber
    • Quicker cooling as neither the hot water in the chamber nor the separate steam generator need to be cooled
    • After cooling, steam is immediately available for the next sterilization run.
    Condensation of steam instead of removal

    Exhaust steam is condensed automatically via a PT-100-regulated cooling system. This prevents odors and protects waste water piping that may be made of plastic.

     

    Pressure-safe up to 5 bar/150 °C

    The Systec D2D-Series double door autoclave units are the first of its kind to be designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing pass through autoclave units.

    Systec pass through autoclave units are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

    pass through autoclave chamber
     

    D2D Series autoclave quality

    Quality materials quality manufacturing

    The pressure vessel of the autoclave is made of corrosion-resistant stainless steel 1.4404 (AISI 316L). The double door autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec D2D-Series sterilizer is ideal for use in clean room environments

    Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

     

    Operation by Touch-Screen technology

    Operation is easy and rapid via a large (5.7 inch) touch screen interface for direct reading. This innovation oers additional options and increased flexibility when working with the autoclave. For example, process data can be displayed numerically or graphically. 7 programs are pre-defined but can be expanded (up to 100) as required by the user. To create a new program, the user is guided through the process by a menu dialog. Every new program is automatically assigned to a permanent, unalterable name and can also be given an individual designation by the user. All process parameters can be individually altered.

    Pre-defined programs
    1. Solids
    2. Waste bags
    3. Liquid waste
    4. Liquids
    5. Cleaning
    6. Vacuum test*
    7. Bowie-Dick test*
    Systec autoclave touchscreen
     

    D2D Series Autoclave Gallery

    [module-289]

  • Autoclave Videos


    Autoclave Videos

    Cooling options to fit your laboratory needs.

    [module-280]

    [module-295]

    [module-296]

    [module-351]

    Design

    Available with four chamber diameter

    Available with four chamber diameter: 400 mm, 500 mm, 740 mm and 1000 mm diameter.

    All-round quality

    The pressure vessel is made of corrosion-resistant stainless steel 316L (1.4404) and is easy to clean. An approved safety valve for excess pressure is included. The autoclave support framework and housing are also made of stainless steel. The highly efficient, high-quality melamine foam insulation material releases no particles; Systec autoclaves can be used under clean-room conditions.

    Dual sensors as standard

    Temperature and pressure are controlled via an electronic pressure sensor, as well as a flexible temperature sensor in the chamber or in a reference vessel (with liquids). Systec HX autoclaves also have an additional temperature sensor in the floor drain.

    Combinated heating

    The combined heating function supplements the built-in steam generator with an external steam heating. A program can be configured to use the internal or external steam heating option. The external steam is supplied at its own connection by the customer‘s facility.


    Diameter 740mm

    Diameter 1000mm
    Systec autoclaves are fitted with the following connections at the rear:
    Demineralized water inlet for steam generation
  • Compressed air (Systec HX-65 to HX-200)
  • Compressed air (Systec HX-210 to HX-1580)
  • Cooling water
  • Common outlet
  • Network /USB
  • Flexible cord with CEE plug
  • Connection to cooling circuit (Systec HX-65 to HX-200)
  • Connection to cooling circuit (Systec HX-210 to HX-1580)
    • = Standard
    •   
    • = Optional

    All according to standards and regulations

    The pressure vessel of the Systec H-Series is designed for operations at 150 °C and 5 bar absolute pressure. Optional temperature and pressure range extension accessories adapt all control and safety components to the higher temperature and pressure. This option can be retrofitted.

    Pressure vessel:
    • 2014/68/EU Pressure Equipment Directive
    • ASME Boiler & Pressure Vessel Code, Section VIII, Division 1
    • China Stamp
    Other guidelines:
    • 2014 / 35 / EU Low Voltage Directive
    • 2014 /30 / EU on Electromagnetic Compatibility
    • 2006 / 42 / EC Machinery Directive
    All autoclaves are CE marked. We will be happy to provide a complete list of standards and summary of regulations on request.

    Options for documentation

    [module-352]
  • Free-standing 21 CFR Part 11 Compliant Autoclaves

    Large Autoclave

    Select size range

    [module-271]

    HX Series Brochure

    Systec Autoclaves Give You Data Control and Documentation

    Your advanced Systec autoclave stores cycle data that can be downloaded from the autoclave, or transferred directly to your network via FTP as PDF and/or CSV (Excel) files. Both documents are electronically signed by the autoclave. This electronic signature is unique and specific to each autoclave. Manual manipulation of any data will result in the file being marked as invalid.

    The advanced 21 CFR Part 11 solution includes:

    • Extended user account control with customizable access, group assignments and more.
    • AuditTrail: all executed actions are documented and can be traced back to the respective user and time stamp
    • There are up to five fields for electronic signatures

    Communication Options:

    • FTP – data can be automatically sent to the server or PC and the end of the autoclave cycle
    • Systec Connect DS – Optional app that can be installed on PC, tablet or smartphone. Allows for viewing of real time data and archiving after cycle completion. Systec Connect DS requires
    • no installation to the customer’s network
    • OPC-UA – Transfer of data in real time to a SCADA or LIMS
    • USB – Standard on all systems for transfer of PDF cycle runs
    • Printer – Optional printer that will print cycle data

    Innovative automatic safety door lock

    Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

    The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

    The door-locking system on this high capacity autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

    large autoclave lock

    autoclave steam generator

    Steam generation

    A steam generator is incorporated in the sterilizer housing providing substantial benefits:

    • No heating elements and no reservoir for dirty water in the chamber
    • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
    • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
    • Accuracy better than ± 0.5° C with empty chamber
    • Quicker cooling as neither the hot water in the chamber nor the separate steam generator need to be cooled
    • After cooling, steam is immediately available for the next sterilization run.
     

    Pressure-safe up to 5 bar/150 °C

    The Systec H-Series high capcity autoclave units are the first of its kind to be designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing H-series horizontal floor standing autoclave units.

    Systec H-Series high capcity autoclaves are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

    autoclave chamber
     

    high capacity autoclave quality

    Quality materials quality manufacturing

    The pressure vessel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. The large capacity autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec HX-Series sterilizer is ideal for use in clean room environments

    Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

     

    Controls – new generation

    The Systec high capacity autoclaves have a “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The microprocessor, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

    Menu-presented instructions in easy to read text form. An advanced touch screen with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position.

    HX Series autoclave touch screen
     

    HX Series Autoclave Gallery

    [module-285]

  • Autoclave Videos


    Autoclave Videos

    Cooling options to fit your laboratory needs.

    [module-280]

    [module-295]

    [module-296]

  • Free-standing 21 CFR Part 11 Compliant Autoclaves 2021

    Large Autoclave

    Select size range

    [module-348]

    HX Series Brochure

    Innovative automatic safety door lock

    Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

    The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

    The door-locking system on this high capacity autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

    large autoclave lock

    autoclave steam generator

    Steam generation

    A steam generator is incorporated in the sterilizer housing providing substantial benefits:

    • No heating elements and no reservoir for dirty water in the chamber
    • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
    • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
    • Accuracy better than ± 0.5° C with empty chamber
    • Quicker cooling as neither the hot water in the chamber nor the separate steam generator need to be cooled
    • After cooling, steam is immediately available for the next sterilization run.
     

    Pressure-safe up to 5 bar/150 °C

    The Systec H-Series high capcity autoclave units are the first of its kind to be designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing H-series horizontal floor standing autoclave units.

    Systec H-Series high capcity autoclaves are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

    autoclave chamber
     

    high capacity autoclave quality

    Quality materials quality manufacturing

    The pressure vessel of the autoclave is made of corrosion-resistant stainless steel 1.4404 (AISI 316L). The large capacity autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec HX-Series sterilizer is ideal for use in clean room environments

    Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

     

    Controls – new generation

    The Systec high capacity autoclaves have a “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The microprocessor, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

    Menu-presented instructions in easy to read text form. An advanced touch screen with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position.

    HX Series autoclave touch screen
     

    HX Series Autoclave Gallery

    [module-285]

  • Autoclave Videos


    Autoclave Videos

    Cooling options to fit your laboratory needs.

    [module-280]

    [module-295]

    [module-296]

    [module-351]

    Design

    Available with four chamber diameter

    Available with four chamber diameter: 400 mm, 500 mm, 740 mm and 1000 mm diameter.

    All-round quality

    The pressure vessel is made of corrosion-resistant stainless steel 316L (1.4404) and is easy to clean. An approved safety valve for excess pressure is included. The autoclave support framework and housing are also made of stainless steel. The highly efficient, high-quality melamine foam insulation material releases no particles; Systec autoclaves can be used under clean-room conditions.

    Dual sensors as standard

    Temperature and pressure are controlled via an electronic pressure sensor, as well as a flexible temperature sensor in the chamber or in a reference vessel (with liquids). Systec HX autoclaves also have an additional temperature sensor in the floor drain.

    Combinated heating

    The combined heating function supplements the built-in steam generator with an external steam heating. A program can be configured to use the internal or external steam heating option. The external steam is supplied at its own connection by the customer‘s facility.


    Diameter 740mm

    Diameter 1000mm
    Systec autoclaves are fitted with the following connections at the rear:
    Demineralized water inlet for steam generation
  • Compressed air (Systec HX-65 to HX-200)
  • Compressed air (Systec HX-210 to HX-1580)
  • Cooling water
  • Common outlet
  • Network /USB
  • Flexible cord with CEE plug
  • Connection to cooling circuit (Systec HX-65 to HX-200)
  • Connection to cooling circuit (Systec HX-210 to HX-1580)
    • = Standard
    •   
    • = Optional

    All according to standards and regulations

    The pressure vessel of the Systec H-Series is designed for operations at 150 °C and 5 bar absolute pressure. Optional temperature and pressure range extension accessories adapt all control and safety components to the higher temperature and pressure. This option can be retrofitted.

    Pressure vessel:
    • 2014/68/EU Pressure Equipment Directive
    • ASME Boiler & Pressure Vessel Code, Section VIII, Division 1
    • China Stamp
    Other guidelines:
    • 2014 / 35 / EU Low Voltage Directive
    • 2014 /30 / EU on Electromagnetic Compatibility
    • 2006 / 42 / EC Machinery Directive
    All autoclaves are CE marked. We will be happy to provide a complete list of standards and summary of regulations on request.

    Options for documentation

    [module-352]
  • IQ/OQ/PQ Services for Systec Autoclaves

    autoclave IQOQ banner

    Microbiology International provides a full range of IQ OQ PQ services for its range of Systec autoclaves and Systec MediaPrep machines.

    Our Qualification Services provide, at your location, the most efficient way to achieve and maintain compliance. In addition, we will provide full documentation by supplying reports on installation, operational and performance qualification of your equipment. 

    What is performed during IQ OQ and PQ?

    Installation Qualification (IQ):   This process reviews the pre-installation detail that the equipment, its component parts and location, are fit for the purpose and satisfy the objectives of the user to carry out the intended function to expected standards.
    The IQ qualifies the equipment is installed correctly with proper facility supplies and connections.  This Pre-qualification checks that manufacturer’s documentation, conformity and calibration detail is present.

    Operations Qualification (OQ):  This process is carried out at installation to verify the performance criteria presented by the manufacturer, to confirm the instrument satisfies its agreed metrics and is valid in the working environment by verification against traceable references.

    Performance Qualification (PQ): This process refers to the test or validation protocol carried out by the user, offering documentary evidence that the instrument is maintaining the agreed values.

    pic8

    pic6

    pic3

    pic4

    pic5

    pic7

     
  • Vertical Autoclaves

    Floor Standing Autoclave
    Type V-40 V-55 V-65 V-75 V-95 V-100 V-120 V-150
    Chamber Dimensions in mm.
    (diameter x depth)
    344 x 450 344 x 600 400 x 500 400 x 600 400 x 750 500 x 500 500 x 600 500 x 750
    External Dimensions in mm.
    Width 500 500 550 550 550 650 650 650
    Height 920 920 960 960 1080 985 985 1110
    Depth 740 740 780 780 780 900 900 900
    Weight (lbs/kg) 242/110 253/115 275/125 286/130 308/140 385/175 396/180 418/190
    Chamber Volume in Liters 40 55 65 75 95 100 120 150
    V Series Brochure Larger Autoclaves

    Loading Capacity

    [module-276]

     

    Innovative automatic safety door lock

    Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

    The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

    The door-locking system on this vertical autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

    vertical autoclave lock
     

    Systec autoclave steam

    Steam generation

    A steam generator is incorporated in the sterilizer housing providing substantial benefits:

    • No heating elements and no reservoir for dirty water in the chamber
    • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
    • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
    • Accuracy better than ± 0.5° C with empty chamber
    • Quicker cooling as neither the hot water in the chamber nor the separate steam generator need to be cooled
    • After cooling, steam is immediately available for the next sterilization run.
     

    Pressure-safe up to 5 bar/150 °C

    The Systec V-Series vertical autoclave units are the first of its kind to be designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing V-series floor standing autoclave units.

    Systec vertical autoclaves are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

    floor standing autoclave lid opened
     

    Systec V series autoclave quality

    Quality materials quality manufacturing

    The pressure vessel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. The vertical autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec V-Series sterilizer is ideal for use in clean room environments

    Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

     

    Controls – new generation

    The Systec floor standing autoclave units have “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The microprocessor, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

    Menu-presented instructions in easy to read text form. Membrane keyboard with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position.

    Floor standing autoclave controls
     

    Vertical Autoclave Gallery

    [module-284]

  • Autoclave Videos


    Autoclave Videos

    Cooling options to fit your laboratory needs.

    [module-298]

    [module-294]

    [module-293]