D2D Series

PDF Print E-mail
Written by Lindsey Sherman   
Wednesday, 04 February 2009 16:52
D2D Series

 

01_ble_007
05_fla_004

 

Chamber Size

Type D2D-90 D2D-150 D2D-200
Chamber dimensions in mm (diameter x depth) 400 x 750 500 x 750 500 x 1000
Chamber volume in liters 95 150 200

Loading Capacity

Erlenmeyer flasks
Type D2D-90 D2D-150 D2D-200
250 ml 31 2 x 42 2 x 59
500 ml 21 2 x 24 2 x 40
1000 ml 13 18 23
2000 ml 8 9 14
3000 ml 4 8 11
5000 ml - 5 7
Scott-Duran media flasks
Type D2D-90 D2D-150 D2D-200
250 ml 40 2 x 54 2 x 83
500 ml 31 2 x 40 2 x 59
1000 ml 18 26 40
2000 ml 10 14 23
5000 ml 4 8 11
10000 ml - 3 4
08_150_blenden
09_wand
View from sterile side
View from non-sterile side

 

Equipped with the same state-of-the-art technology as our04_wand_007V&D series autoclaves, the D2D has the same modern design but now with two doors for fitting between separating walls. The autoclaves are specially designed for gas-tight fitting to separating walls. The installation area comprising all technical components is located on the external, non-sterile side with a natural environment. Operation, however, can be carried out from both sides, the position (open or closed) of the opposite door being indicated on the display.

For use under the most stringent clean room and safety conditions:

-For biological safety laboratories. Fitting as a sterilization and double-door (pass-through) lock for protecting the external environment

-For clean rooms in laboratories and production facilities as a sterilization and double-door lock separating sterile and non-sterile areas.

Triple Safety Aspects!02_wand_005

-Only one door can be opened at a time. If one door is open, the other is automatically locked. (Images with both doors open are for demonstration and display purposes only)

-If the autoclave is switched off or if no current is available (power failure) both doors remain locked.

-If the door at the non-sterile side is opened, a sterilization program has to be run before the door at the sterile side can be opened.

The locking system can be adapted to customer's preferences. Doors and control panel are made of heat-insulating plastic, the housing completely of stainless steel and the edges chamfered for smooth junctions with walls.

Equipped with the same state-of-the-art technology as our V&D series autoclaves, the D2D has the same modern design but now with two doors for fitting between separating walls.

Features:
Innovative automatic safety door lock.

Easy and safe. When the lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds the seal becomes tighter. The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.
The door-locking system is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the operator coming into contact with hot components.

dseries_clip_image004

dseries_clip_image006

dseries_clip_image008

Pressure-safe up to 5 bar/150 °C.
Tomorrow’s process requirements are addressed in today’s design!
The Systec V-Series autoclaves are the first of its kind t o be designed for higher pressures and temperatures. The standard pressure chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the
higher temperature and pressure. This option may be retrofitted to existing V- series autoclaves.

Systec V-Series autoclaves are equipped direct from the factory for sterilization
temperatures up to 140 °C and 4 bar of pressure.

06_voll_001_weiss

Controls – new generation.
Microprocessor and software
The Systec V-Series autoclaves have “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The microprocessor, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

Menu-presented instructions in easy to read text form.Membrane keyboard with acoustic confirmation signal. Ergonomically located in a logical and easy tooperate position.

dseries_clip_image012

Design – pure innovation!

Steam generation!
A steam generator is incorporated in the housing providing substantial benefits:

– No heating elements and no reservoir for dirty water in the chamber
– With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
– Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
– Accuracy better than ± 0.3 C with empty chamber
– Quicker cooling as neither hot water in the chamber nor the separate steam generator need be cooled
– After cooling, steam is immediately available for the next sterilization run.

designsteamgeneration

Further standard features:
– Flexible temperature sensor PT-100 for a reference vessel
– Medium temperature triggering of sterilization time
– Autofill – automatic filling with demineralized water feed for steam generation
– Start by clock – timer for programming starting time
– Collecting point for all outlet pipes
– Venting valve
– Baseplate in the chamber for vessels, baskets etc.
– Validation port

dseries_clip_image016

PT-100 temperature sensor

Condensation instead of steam removal!
Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.
Quality materials quality manufacturing!
The pressure v essel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. Autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec V-Series is ideal for use in clean room environments.

dseries_clip_image018

pdfSystec D series Brochure
pdfContamination Control Autoclaves

 

D-Series Model D2D-90 D2D-150 D2D-200
Chamber dimensions
(diameter x depth) mm
400 x 750 500 x 750 500 x 1000
Chamber Volume (Liters) 95 150 200
Max. working chamber pressure (bar) -1 to +4 -1 to +4 -1 to +4
Max. working chamber temp.
(Celsius)
-10 to 150 -10 to 150 -10 to 150
Max. working steam
generator pressure (bar)
5 5 5
Max. working steam generator temp. (Celsius) 160 160 160
Heating Capacity (Watts) 9000 9000 9000
Voltage (Volts) 3 x 220 3 x 220 3 x 220
Power Requirement (Amps) 30 30 30
Weight (kg) 190 250 310
Neccessary Connections
Tap water, DI water, Drain, Compressed air Tap water, DI water, Drain, Compressed air Tap water, DI water, Drain, Compressed air

 

schematic_chart
Dimensions (mm)

 

D2D-90 D2D-150 D2D-200
A 750 850 850
B 1030 1130 1130
C 1430 1530 1530
D 1570 1670 1670
E 240 260 260
F max. 200 max. 200 max. 200
G 900 900 1150
H 920 1020 1020
I 780 880 880
J 820 920 920
K 800 800 800
L 670 770 770

 

Type of basket/ insert Stainless steel wire
baskets
Stainless steel bucket
for waste material
Dimensions
(L x W x H) mm
Capacity Dimensions
(L x W x H) mm
Capacity
D2D-90 700 x 300 x 250 1 700 x 300 x 150 1
D2D-150 360 x 380 x 250 2 355 x 375 x 200 2
750 x 380 x 250 1 715 x 375 x 200 1
360 x 380 x 135 4
750 x 380 x 135 2
D2D-200 500 x 380 x250 2 500 x 375 x 200 2
500 x 380 x 135 4

 

 

Printer for documentation

Print program type, batch number, date, time, temperature, pressure and sterilization phase for total traceability

dseries_ticket_priner.jpg


 

 

PC software

For documentation during sterilization program. Download and save all cycle information.

Additional use for service and diagnosis of instrument electronics.

pc_software.jpg

 

 

Stainless Steel Wire Mesh Basket

Used for sterilizing liquids, open containers, non-waste materials


dseries_baskets.jpg

Stainless Steel closed basket for waste sterilization

Used for waste sterilization

 

 


Air compressor – Silent 50
Used for quick cooling if compressed air is not available.


Conductivity meter
For validation of PT100 temperature probes


Condensate collection vessel
For units not connected to constant De-Ionized water supply


Demineralization cartridge
Stainless steel. For connection to “hard” water supply.

 

You may also be interested in this/these product(s):

vseries V Series
Simply the most advanced line of autoclaves available. Full electronic control with automated door sealing, built in steam generator, PT100 temperature probe, 12 user defined programs, 50% faster heat-up times and 90% shorter cooling times.
mediaprep Systec MediaPrep
Fully automated media sterilizers with active cooling; provides rapid cycle times for busy laboratories. Available in 12, 25, 40, 70 and 110 liter sizes. Features include fully programmable microprocessor controlled operation, rapid dispense capability,

 

Last Updated on Wednesday, 24 February 2010 12:03